Introduction

Colorectal cancer (CRC) is the third most common cancer worldwide and the second most common in Europe and the United States. It constitutes approximately 10% of all cancers observed in men and women [13]. Over 90% of CRC cases follow an adenoma-to-cancer sequence over many years [4]. Colorectal cancer screening has been successful in reducing the incidence and mortality of CRC by increasing the proportion diagnosed at an early stage and facilitating removal of pre-neoplastic lesions [5]. Colonoscopy is currently the preferred method for screening, decreasing the incidence of CRC by up to 80% [6, 7]. This beneficial effect is strongly associated with the adenoma detection rate (ADR), which is the single most important quality surrogate for screening colonoscopy. The definition of ADR suggested by the English Bowel Cancer Screening Programme is the number of colonoscopies at which one or more histologically confirmed adenomas is found divided by the total number of colonoscopies performed. According to the most recent European Society of Gastrointestinal Endoscopy (ESGE) recommendations, ADR should be at the minimum level of 25%. The goal of the modern colonoscopy quality improvement is to reduce the operator dependence, and generally to move low-level performers toward high-end performance as rapidly as possible.

Poor cecal intubation rate (CIR) correlates with a low adenoma detection rate, and it is closely associated with an increased risk of post-colonoscopy colorectal cancer (PCCRC). Within recent years different endoscopic imaging techniques have been introduced to improve the quality of colonoscopy and CRC screening. We have witnessed the transition from fiberscopes to videoscopes, which already has significantly increased the diagnostic capability of endoscopes. Following the introduction of videoscopes, the structure of the endoscopes has been changed nowadays. Responsive insertion technology (RIT) combines three technologies, passive bending (PB), high-force transmission (HFT), and variable stiffness, to facilitate the feasibility of the examination, increasing the CIR, and increasing the patient’s comfort. The new endoscopes also include narrow band imaging (NBI), near focus (NF) and magnetic endoscopic imaging (MEI) – novelties that are supposed to reduce the adenoma miss rate.

Our aim was to evaluate the quality of colonoscopy expressed by ADR in two different eras of endoscopic technology advancement.

Material and methods

We conducted a retrospective dual-center study in the 2nd Department of Surgery, Jagiellonian University Medical College and the Specialist Diagnostic and Therapeutic Center “Medicina” in Krakow, Poland. The study was approved by the local ethics committee and conducted in accordance with the principles of the Declaration of Helsinki (KBN no. 122.6120.36.2016).

Patients

We selected 24 055 patients aged 40-65 who underwent colonoscopy screening between January 2000 and December 2014 (as part of a national colorectal cancer screening program, which was financed by the Polish Ministry of Health). Patients with a prior history of abdominopelvic surgery, inflammatory bowel disease, active malignancy, and a high anesthetic risk (ASA IV) were excluded from the study. All patients were pre-evaluated before the examination and written informed consent for the procedure was obtained. Bowel preparation was accomplished using verbal and written information. Patients were informed to take a liquid propulsive agent (i.e., 420 g of polyethylene glycol (PEG) in 4 l of water) in the evening prior to the procedure for morning patients and a split-dose regimen for those in the afternoon schedule.

Setting

We used Olympus series colonoscopes (Olympus Optical Co. Ltd, Tokyo, Japan). Patients were sorted into two groups according to the endoscopic equipment used for colonoscopic examination.

Group I included 10 405 patients examined between 2004 and 2008. This era encompasses the use of electronic endoscopes with a standard resolution (CF-Q145, CF-Q165, and CF-Q180).

Between 2009 and 2014, we performed 13 650 colonoscopies using the CF-HQ190L (group II). This was the era of endoscopes with a high-definition resolution, magnetic scope guide, responsive insertion technology (RIT) and narrow band imaging (NBI) with dual focus two-stage optical lens technology (Table I).

Table I

Parameters of endoscopes used in the study

Endoscopes used in group I (2004–2008)
Olympus CF-Q145:
  • Diameter: 12.8 mm

  • Working length: 168 cm

  • Instrument channel: 3.7 mm

  • Field of view: 140°

  • Angulation range: up: 180, down: 180, right: 160, left 160

Olympus CF-Q165:
  • Diameter: 12.8 mm

  • Working length: 168 cm

  • Instrument channel: 3.7 mm

  • Field of view: 140°

  • Angulation range: up: 180, down: 180, right: 160, left 160

Olympus CF-Q180:
  • Diameter: 12.8 mm

  • Working length: 168 cm

  • Instrument channel: 3.7 mm

  • Field of view: 170°

  • Angulation range: up: 180, down: 180, right: 160, left 160

  • Features: variable stiffness technology

Endoscopes used in group II (2009–2014)
Olympus CF-HQ190L:
  • Diameter: 12.8 mm

  • Working length: 168 cm

  • Instrument channel: 3.7 mm

  • Field of view: 170°, near 160°

  • Angulation range: up: 180, down: 180, right: 160, left 160

  • Features: variable stiffness technology, narrow band imaging (NBI), responsive insertion technology (RIT), scope guide, high definition (HD) (1280 × 1024 pixels)

Patients’ preoperative characteristics including demographics, body mass index (BMI), family history of malignancy and significant comorbidities were determined.

Outcome

Ten experienced endoscopists conducted the procedures, each having independently performed over 1000 colonoscopies, certified by the Polish Society of Surgeons. The ADR was determined as the number of colonoscopies in which one or more histologically confirmed adenomas were found divided by the total number of colonoscopies performed. We compared the adenoma detection rate (ADR) and mean adenoma number per colonoscopy in two successive eras of endoscopic technological development according to the series of the endoscope used. We compared the procedures per room ratio (PPR – a parameter that describes the approximate capacity of procedures per room, representing the mean number of procedures done daily in one colonoscopy office). Other endpoints of the study influencing the ADR were analyzed: completeness of examination, bowel preparation assessment (5-point scale), and patient tolerance for examination (4-point scale). Pathological results were also presented.

Statistical analysis

All data were analyzed with StatSoft Statistica v.12.5 (StatSoft Inc, Tulsa, Oklahoma, USA). The results are presented as mean ± standard deviation (SD), or median and interquartile range (IQR), when appropriate. The study of categorical variables used Pearson’s χ2 test, or χ2 with Yates correction when appropriate. The Shapiro-Wilk test was used to check for normal distribution of data. Quantitative data were analyzed with Student’s t-test (for normally distributed data) or the Mann-Whitney test (for non-normally distributed data). Univariate and multivariate logistic regression models were built including continuous and categorical variables. Results were considered statistically significant when the p-value was found to be less than 0.05.

Results

We observed no difference between the groups regarding sex and age (p = 0.790 and 0.404, respectively). Body mass index was slightly higher in group II (p < 0.001). Family history of malignancy was more prevalent in group II (43% vs. 41.18%, p = 0.010). Patients in this group had more significant comorbidities than in group I (21.87% vs. 8.89%, p < 0.001). Complete colonoscopies were performed more frequently in group II (96.68% vs. 93.73%, p < 0.001) and the adenoma detection rate was higher in group II (31.73% vs. 29.14%, p < 0.001) along with mean adenoma number per colonoscopy (p < 0.001). Procedures per room ratio (PPR) was comparable (p = 0.088). Patients in groups I and II differed slightly, yet statistically significantly, in terms of bowel preparation and tolerance of examination (p < 0.001). Bowel preparation assessment was classified as follows: 1 – poor, 2 – substandard, 3 – adequate, 4 – good, 5 – excellent. Patients’ tolerance of colonoscopy was described as follows: 1 – severe discomfort, 2 – moderate discomfort, 3 – mild discomfort, 4 – no or minimal discomfort. Basic characteristics and comparison between group I and group II are presented in Table II.

Table II

Comparison between groups

ParameterAllGroup IGroup IIP-value
Sex M/F, n (%)9007/13841 (39%/61%)2881/4404 (40%/60%)6126/9437 (39%/61%)0.790
Age, mean ± SD [years]54 ±754 ±654 ±70.404
BMI, mean ± SD [kg/m2]26.87 ±4.7426.56 ±3.926.97 ±4.97< 0.001
Malignancy in family history, n (%)9692 (42.42)3000 (41.18)6692 (43.00)0.010
Significant comorbidity, n (%)4051 (17.73)648 (8.89)3403 (21.87)< 0.001
Full/incomplete examinations, n (%)21875/973 (95.74/4.26)6828/457 (93.73/6.27)15047/516 (96.68/3.32)< 0.001
PPR10.29 ±6.889.95 ±6.2210.46 ±7.170.088
Adenoma detection rate – ADR (%)30.8829.1431.73< 0.001
Adenoma number per colonoscopy, mean ± SD (95% CI)0.366 ±0.715 (0.357–0.375)0.337 ±0.683 (0.321–0.352)0.380 ±0.728 (0.369–0.392)< 0.001
Bowel preparation assessment*, n (%):
 520726 (90.71)6824 (93.67)13902 (89.27)< 0.001
 4377 (1.65)86 (1.18)291 (1.87)
 3712 (3.12)266 (3.65)446 (2.87)
 2271 (1.19)90 (1.24)181 (1.16)
 167 (0.29)19 (0.26)48 (0.31)
Patient tolerance for exam*, n (%):
 421838 (95.58)6988 (95.92)14850 (95.42)< 0.001
 3305 (1.33)117 (1.61)188 (1.21)
 2265 (1.16)63 (0.86)202 (1.30)
 1305 (1.33)117 (1.61)188 (1.21)

PPR – procedures per room, parameter that describes approximate capacity of procedures per room, representing mean number of procedures done daily in one colonoscopy office.

* Bowel preparation assessment classification: 1 – poor, 2 – substandard, 3 – adequate, 4 – good, 5 – excellent. **Patient tolerance of colonoscopy classification: 1 – severe discomfort, 2 – moderate discomfort, 3 – mild discomfort, 4 – no or minimal discomfort.

Table III presents univariate logistic regression analysis of influence of selected factors on completeness of examinations. Significant factors were patients’ sex, age, BMI, bowel preparation, tolerance and examination performed in group II. They were included in multivariate logistic regression in Table IV. Multivariate logistic regression analysis of the influence of selected factors on completeness of examinations revealed that patients’ sex, BMI, bowel preparation, tolerance and colonoscopy performed in the era of modern endoscopes were significant independent factors that resulted in completeness of examinations.

Table III

Univariate logistic regression analysis of influence of selected factors on completeness of examinations

ParameterOR95% CIP-value
Sex, M vs. F0.430.37–0.51< 0.001
Age, with every year0.990.98–0.990.049
BMI, with every 1 kg/m20.930.91–0.95< 0.001
Significant comorbidity1.050.47–2.340.905
Bowel preparation assessment, with every grade higher1.951.88–2.02< 0.001
Patient tolerance for exam, with every grade higher4.524.19–4.87< 0.001
Group 1 vs. 21.951.71–2.22< 0.001

[i] OR – odds ratio, CI – confidence interval.

Table IV

Multivariate logistic regression analysis of influence of selected factors on completeness of examinations

ParameterOR95% CIP-value
Sex, M vs. F0.590.49–0.71< 0.001
BMI, with every 1 kg/m20.960.94–0.98< 0.001
Bowel preparation assessment, with every grade higher2.111.94–2.29< 0.001
Patient tolerance for exam, with every grade higher4.674.28–5.10< 0.001
Group 1 vs. 21.911.60–2.27< 0.001

[i] OR – odds ratio, CI – confidence interval.

Univariate logistic regression analysis of the influence of selected factors on the adenoma detection rate (ADR) is presented in Table V. Male sex, age, BMI, bowel preparation, completeness of examinations, patient’s tolerance for examination and colonoscopies performed in group II increased ADR. Then significant factors were included in the multivariate logistic regression analysis presented in Table VI: male sex, age, BMI, bowel preparation, completeness of examinations and examinations performed in the modern endoscope era (group II) increased ADR as independent factors.

Table V

Univariate logistic regression analysis of influence of selected factors on ADR

ParameterOR95% CIP-value
Sex, F vs. M1.821.69–1.92< 0.001
Age, with every year1.031.02–1.04< 0.001
BMI, with every 1 kg/m21.031.02–1.04< 0.001
Significant comorbidity1.060.98–1.150.124
Bowel preparation assessment, with every grade higher1.191.11–1.27< 0.001
Patient tolerance for exam, with every grade higher1.311.20–1.43< 0.001
Completeness of examinations2.091.73–2.53< 0.001
Group 1 vs. 21.131.05–1.220.001

[i] OR – odds ratio, CI – confidence interval.

Table VI

Multivariate logistic regression analysis of influence of selected factors on ADR

ParameterOR95% CIP-value
Sex, F vs. M1.821.69–1.96< 0.001
Age, with every year1.031.02–1.04< 0.001
BMI, with every 1 kg/m21.021.01–1.03< 0.001
Bowel preparation assessment, with every grade higher1.171.09–1.26< 0.001
Patient tolerance for exam, with every grade higher1.060.95–1.180.271
Completeness of examinations1.791.41–2.26< 0.001
Group 1 vs. 21.131.04–1.220.004

[i] OR – odds ratio, CI – confidence interval.

The overall ADR was 30.88–38.80% and 25.95% for the male and female patients, respectively. The mean adenoma number per colonoscopy was 0.366 (95% CI: 0.357–0.375) – 0.483 (0.466–0.500) and 0.290 (0.280–0.301) for the male and female patients, respectively.

Table VII presents the adenoma detection rate in relation to specific factors that influenced ADR in the logistic regression model.

Table VII

Comparison of ADR in selected parameters

ParameterADR (%)P-value
Sex, F vs. M25.95/38.80< 0.001
Age [years]:
 50–5527.82< 0.001
 56–6032.08
 61–6533.43%
BMI [kg/m2]:
 < 2528.17< 0.001
 25–3031.71
 30–3534.60
 ≥ 3536.82
Significant comorbidity, Yes/no31.96/30.620.132
Malignancy in family, Yes/no31.09/30.820.751
Bowel preparation assessment*:
 532.26< 0.001
 423.86
 323.65
 230.10
 111.54
Patient tolerance for exam**:
 431.32< 0.001
 322.19
 221.13
 118.35
Complete vs. incomplete examination31.47/18.01< 0.001
Group 1 vs. 229.14/31.730.001

* Bowel preparation assessment classification: 1 – poor, 2 – substandard, 3 – adequate, 4 – good, 5 – excellent.

** Patient tolerance of colonoscopy classification: 1 – severe discomfort, 2 – moderate discomfort, 3 – mild discomfort, 4 – no or minimal discomfort.

Tables VIII and IX present comparisons of histopathological findings respectively in distal and proximal colon between groups with p-values of inter-group comparisons.

Table VIII

Comparison of histopathological findings in distal colon between groups

ParameterAllGroup IGroup IIP-value
Total number of exams with samples for pathological exam3501 (15.32%)1187 (16.29%)2337 (15.02%)0.013
Non-neoplastic lesions1509 (6.60%)559 (7.67%)950 (6.10%)< 0.001
Hyperplastic polyp422 (1.85%)141 (1.94%)281 (1.81%)0.497
Benign non-epithelial neoplasm123 (0.54%)36 (0.49%)87 (0.56%)0.532
1–2 Tubular adenomas < 10 mm1059 (4.63%)283 (3.88%)776 (4.99%)< 0.001
3–4 Tubular adenomas < 10 mm29 (0.13%)5 (0.07%)24 (0.15%)0.135
≥ 5 Tubular adenomas < 10 mm3 (0.01%)03 (0.02%)
Tubular adenoma ≥ 10 mm97 (0.42%)38 (0.52%)59 (0.38%)0.122
1–2 Tubular-villous adenomas < 10 mm58 (0.25%)24 (0.33%)34 (0.22%)0.120
≥ 5 Tubular-villous adenomas < 10 mm1 (< 0.01%)1 (0.01%)0
Tubular-villous adenoma ≥ 10 mm34 (0.15%)16 (0.22%)18 (0.12%)0.057
Villous adenoma < 10 mm4 (0.02%)2 (0.03%)2 (0.01%)0.810
Villous adenoma ≥ 10 mm3 (0.01%)3 (0.04%)0
Polyp with high grade dysplasia < 10 mm54 (0.24%)22 (0.30%)32 (0.21%)0.211
Polyp with high grade dysplasia ≥ 10 mm28 (0.12%)8 (0.11%)20 (0.13%)0.862
Invasive adenocarcinoma in polyp6 (0.03%)3 (0.04%)3 (0.02%)0.607
Non-epithelial malignant neoplasm1 (< 0.01%)01 (0.01%)
Macroscopic adenocarcinoma70 (0.31%)23 (0.32%)47 (0.30%)0.861
Table IX

Comparison of histopathological findings in proximal colon between groups

ParameterAllGroup IGroup IIP-value
Total number of exams with samples for pathological exam12943 (56.65%)4618 (63.39%)8325 (53.49%)< 0.001
Non-neoplastic lesions8331 (36.46%)3086 (42.36%)5245 (33.70%)< 0.001
Hyperplastic polyp1957 (8.57%)658 (9.03%)1299 (8.35%)0.084
Benign non-epithelial neoplasm44 (0.60%)17 (0.23%)27 (0.17%)0.336
1–2 Tubular adenomas < 10 mm1483 (20.36%)413 (5.67%)1070 (6.88%)0.006
3–4 Tubular adenomas < 10 mm44 (0.19%)13 (0.18%)31 (0.20%)0.739
≥ 5 Tubular adenomas < 10 mm11 (0.05%)3 (0.04%)8 (0.01%)0.996
Tubular adenoma ≥ 10 mm286 (1.25%)119 (1.63%)167 (1.07%)< 0.001
1–2 Tubular-villous adenomas < 10 mm148 (0.65%)64 (0.88%)84 (0.54%)0.003
3–4 Tubular-villous adenomas < 10 mm4 (0.02%)3 (0.04%)1 (0.01%)0.189
Tubular-villous adenoma ≥ 10 mm107 (0.47%)52 (0.71%)55 (0.35%)< 0.001
Villous adenoma < 10 mm4 (0.02%)3 (0.04%)1 (0.01%)0.189
Villous adenoma ≥ 10 mm20 (0.09%)13 (0.18%)7 (0.04%)0.003
Polyp with high grade dysplasia < 10 mm108 (0.47%)40 (0.55%)68 (0.44%)0.250
Polyp with high grade dysplasia ≥ 10 mm125 (0.55%)37 (0.51%)88 (0.57%)0.583
Invasive adenocarcinoma in polyp25 (0.11%)9 (0.12%)16 (0.10%)0.659
Non-epithelial malignant neoplasm5 (0.02%)1 (0.01%)4 (0.03%)0.928
Macroscopic adenocarcinoma241 (1.05%)87 (1.19%)154 (0.99%)0.158

Discussion

The single most important outcome to measure the effectiveness of colonoscopy is the ADR, since it is associated with the future risk of CRC occurrence and mortality. Physicians performing screening colonoscopies with ADR below 20% are more likely to have patients subsequently presenting interval cancer [8].

Our results have confirmed some particular circumstances that without a doubt should be maintained to keep the quality of the examinations at the highest possible level. Effective bowel cleansing is one of them. The better the bowel preparation is, the more precise is detection of preneoplastic lesions and the easier is cecal intubation. Poor cleansing of the bowel is associated with prolonged procedures and low ADR. There is heterogeneity among the studies concerning bowel cleansing as to whether split or non-split preparation is more effective. However, tolerance of high volumes of polyethylene glycol (PEG) solution may be low. Splitting the dose may improve it [9]. Authors are now also focusing on the timing of bowel cleansing. The outcome of cleansing appears to be efficient when the examination is commenced within hours of the bowel preparation [10]. The bowel cleansing in our study met the criteria of the European Society of Gastrointestinal Endoscopy, according to which no more than 10% of the examinations should need to be repeated due to inadequate bowel preparation.

Patient-related aspects also have an impact on ADR. Obesity is an independent risk factor of adenoma occurrence. There is a debate concerning body weight and the technical struggle in reaching the cecum during colonoscopy. There is evidence suggesting that both low and high BMI patients are technically demanding for a physician performing the examination [11]. Obesity is also associated with poor bowel preparation, which can subsequently lead to a difficult and prolonged colonoscopy. Our study has revealed that a higher BMI was a factor associated with statistically significantly higher ADR and a higher cecal intubation rate (CIR). It might be due to the low muscle content of a low-BMI patient that may predispose to loop formation and patient intolerance, which leads to unsuccessful colonoscopy. There are studies which revealed that the number of loops formed during the insertion of the endoscope in low-BMI patients is higher than that in obese patients [12].

The ADR varies between men and women. Adenomas are more common in men, which explains our outcome that male sex is an independent factor leading to higher ADR. The American Society for Gastrointestinal Endoscopy (ASGE) recommendations propose that adenomas should be detected in more than 25% of asymptomatic male individuals (> 50 years) and in more than 15% of asymptomatic female individuals (> 50 years) at first. According to studies based on large populations of patients, factors associated with completion of the colonoscopy without sedation include male sex. That explains the higher cecal intubation rate among males in our study [13]. ADR as well as the advanced cancer detection also increases with age. Both men and women with each decade of life after 50 have a statistically higher ADR [14].

Several studies have shown that even certified colonoscopists exhibit variation in the adenoma detection rate. The difference in detecting serrated lesions is even greater than for conventional adenomas. It demonstrates that colonoscopy is a highly operator-dependent procedure [15, 16]. That is why training in differentiation skills is essential.

The benefit of knowing our own ADR may also motivate endoscopic quality improvement, as it has been shown in several interventional studies with the implementation of scheduled personalized ADR report cards [17, 18]. It has been confirmed in recent studies, including a meta-analysis, where patients were undergoing same-day, back-to-back (tandem) colonoscopies, that especially in the right colon polyps are more likely to be missed [19, 20]. Of course failure to reach the cecum leads to low ADR in the right colon as a consequence of excessive loop formation or failure to traverse angulated, fixed, or strictured sigmoids (most commonly among female patients with prior gynecological surgery and patients with advanced diverticular disease). Even if the cecum is intubated successfully, there are factors increasing the adenoma miss rate such as localization behind the folds and flat lesions [21, 22].

Using an effective technique means performing endoscopy with a withdrawal time allowing a physician to keep his ADR level high. There is a strong association of detection of precancerous lesions with withdrawal time. There are studies showing a linear correlation between ADR and withdrawal time, proving that a 6-minute withdrawal time is crucial to maintain the quality of the examination [23, 24].

The role of modern colonoscopy is to improve the quality by reducing the operator dependence. Within recent years different types of endoscopic imaging techniques have been introduced to improve the quality in colonoscopy and as a consequence the colorectal cancer screening. Advanced endoscopic imaging is revolutionizing our current methods to diagnose and treat colorectal lesions.

One of the technologies that has become standard in modern endoscopy is high definition (HD). High definition endoscopes have more pixels than standard definition (SD). Improved image quality should improve lesion detection and recognition. High definition not only helps to visualize lesions during a screening colonoscopy, but it also enhances evaluation of post-polypectomy scars at follow-up. A meta-analysis suggested that the implementation of HD produces a 2% to 4% gain in the ADR [25]. In our study ADR in successive eras of endoscopic technological development has risen. The difference in ADR between the analyzed eras is 2.59%, which is an acceptable level according to the literature.

Another optical enhancement technology present in modern endoscopes is filter technology that uses narrow red-green-blue light bands, i.e. narrow band imaging (NBI), to enhance micro-vessel architecture. There are randomized controlled trials (RCTs) showing the improvement in ADR with the use of NBI compared to standard endoscopies. There is also one study suggesting that NBI may improve the learning curve for detecting flat lesions [26, 27]. Initial studies show that this technology has potential to improve ADR, but we definitely need further investigations. In our study we cannot determine what the real influence on ADR in group II was. Not every report contained the Kudo classification describing the found lesion. However, it was possible to use the NBI whenever the physician performing endoscopy had diagnostic doubts.

In our study we performed a multivariate logistic regression analysis of the influence of selected factors on ADR, which showed that patients’ tolerance is one of the crucial elements. The modern endoscopes that we used in our study are equipped with tools that increase the tolerance of the patients. The variable stiffness of the endoscope and responsive insertion technology (RIT) are features simplifying endoscope insertion and reducing the discomfort and pain during the examination. Undesired loops are reduced when the RIT endoscope is used, because of the secondary bending section of the endoscope and its flexibility. In conventional colonoscopes, when the scope passes through a sharp flexure in the colon, the force applied by the physician when inserting the scope can sometimes directly push up the wall of the colon because the distal end of the scope bends with a small radius (the so-called stick phenomenon). The bending function is useful for preventing the stick phenomenon, which causes severe pain for patients during colonoscopic insertion in colonic flexures [28, 29]. Reduction of loop formation and auxiliary maneuvers when using RIT reduce the patients’ discomfort, leading to higher ADR.

Another technology that has an impact on patients’ tolerance is magnetic endoscopic imaging (MEI) commercialized by Olympus as ScopeGuide (Olympus, Tokyo, Japan). Magnetic endoscopic imaging is a non-radiographic imaging technique capable of displaying real-time three-dimensional images of the colonoscope shaft within the abdominal cavity [30]. The main advantage is the possibility to locate the lesions precisely. However, there are RCTs confirming that use of MEI during colonoscopy has the potential to ease cecal intubation, and reduce patient discomfort and dependence on sedation [31]. Also the MEI system appears to be beneficial for inexperienced endoscopists, and it increases the cecal intubation rate. The technology helps to reduce the number of attempts to straighten loops and the duration of looping. However, experienced endoscopists are likely able to recognize and resolve loops quickly without the need for MEI visualization [32].

Colonoscopy is considered to be a gold standard for CRC screening. However, we still have a lot of work to do, especially considering the adenoma miss rate in the right colon. Many lesions are still missed because of the inability to visualize flat lesions and those located behind the fold. A perfect device should be ergonomic, and effective in its results and costs [33, 34]. According to our experience technologies such as HD, NBI, RIT and MEI meet the above-mentioned criteria and enhance the quality of screening endoscopy. There are several technologies present on the market, such as Full Spectrum Endoscopy (FUSE) and devices fixed to the colonoscope tip for the purpose of flattening folds, including a short cap or hood, Endocuff, Endocuff Vision, and Endoring. Our experience with those technologies is initial. Hence, we need more date to determine whether they can improve ADR. So far the data are mixed with regard to their efficacy.

In conclusion, there has been a technological revolution in endoscopy since the beginning of our study in 2004. We showed that technological innovations, novel endoscopy devices and diagnostic techniques as well as patient-related factors significantly improve the quality of colorectal cancer screening by increasing the adenoma detection rate. Endoscopes of the new era have great potential. However, in the future, we need to determine and standardize which of the technologies are supreme to achieve excellence in colorectal cancer screening.